VICTRON MULTIPLUS 12/3000/120-16 230V VE.BUS INVERTER/CHARGER
The VICTRON MULTIPLUS 12/3000/120-16 230V VE.BUS INVERTER/CHARGER is the most powerful inverter-charger in the Victron Multiplus family, designed for 12-volt batteries. With a continuous output power of 3000VA and a peak power of 6000W, it is perfect for starting motors and handling demanding loads.
- Powerful Battery Charger: Integrated charger manages a current of 120 amps, delivering 1440W of charging power.
- Four-Stage Charging: Ensures optimal battery maintenance and longevity.
- Easy Programming: DIP switches allow for battery type configuration without the need for a programming console.
- Safety Features: Equipped with all necessary protections for safe and reliable operation.
Upgrade your power management with the VICTRON MULTIPLUS and experience unparalleled performance and reliability.
Technical Specifications:
Input voltage: 9.5 - 17 V
Peak power: 6000 W
Continuous output power at 25ºC: 3000VA
Maximum efficiency: 93%
No-load consumption: 10%
CHARGER:
Input voltage range: 187-265 VAC
Absorption charging voltage: 14.4 VDC
Storage mode: 13.2 VDC
House battery charging current: 120 A
Starting battery charging current: 4 A
Battery temperature sensor
GENERAL:
Power control: YES
Transfer switch: 16 A
Protection against: output short circuit, overload, battery voltage too high, battery voltage too low, polarity reversal detection, 230V AC at inverter output, excessive input voltage ripple, excessive temperature
Relay controller
Parallel and/or three-phase operation
Operating temperature: -20 to 50ºC
Maximum humidity: 95%
Connection to batteries with 4 M8 bolts
Connection to 230V AC with 13 mm.2 screw terminals (6 AWG)
Weight: 18 kg
Dimensions: 362x258x218 mm
Complies with safety standards EN60335, EN60335-2-29, and EN 55014 - 1, EN 55014 - 2 /EN 61000 - 3 -2, EN 61000 - 3 - 3.
Advantages
Two AC outputs
The main output has the "no-break" function. The MultiPlus takes care of supplying power to connected loads in case of a blackout or disconnection from the electrical grid/generator. This happens so quickly (in less than 20 milliseconds) that computers and other electronic devices continue to operate without interruption.
The second output is only active when one of the MultiPlus inputs receives AC power. This output can connect devices that should not discharge the battery, such as a water heater, for example (second output available only in models with a 50A transfer switch).
Practically unlimited power thanks to parallel operation
Up to 6 Multis can operate in parallel to achieve greater output power. Six units 24/5000/120, for example, will provide an output power of 25 kW/30 kVA and a load capacity of 720 amperes.
Three-phase operation capability
In addition to parallel connection, three units of the same model can be configured for three-phase output. But that's not all: up to 6 sets of three units can be connected in parallel, providing an output power of 75 kW / 90 kVA and more than 2000 amperes of load capacity.
PowerControl – Limited power from the generator, dock, or grid
The Multi is a very powerful battery charger. Therefore, it will draw a lot of current from the generator or the dock's grid (almost 10 A for each 5kVA Multi at 230 VAC). In the Multi Control Panel, a maximum current from the generator or dock can be set. The MultiPlus will take into account the other AC loads and use the remaining current for charging, thus avoiding overloading the generator or the dock's grid.
PowerAssist – Increased electrical capacity of the dock or generator
This function takes the principle of PowerControl to another dimension. It allows the MultiPlus to complement the capacity of the alternative source. When a power peak is required for a short period, as often happens, MultiPlus will immediately compensate for the possible lack of power from the dock or generator with battery power. When the load decreases, the surplus power is used to recharge the battery.
Variable four-stage charger and dual battery bank charging
The main output provides a powerful charge to the battery system through advanced "variable charging" software. The software precisely adjusts the automatic three-stage process to adapt to battery conditions and adds a fourth stage for prolonged slow charging. The variable charging process is described in more detail in the Phoenix Charger data sheet and on our website under "Technical Information". In addition to the above, the MultiPlus can charge a second battery using a limited independent charging output, designed to charge a starting battery for the main engine or generator (this output is available only in 12V and 24V models).
The system setup couldn't be easier
Once installed, the MultiPlus is ready to operate. If the configuration needs to be changed, it can be done in minutes using a new DIP switch setup procedure. With the DIP switches, parallel and three-phase operation can even be programmed: no computer needed! A VE.Net can also be used instead of the DIP switches. And sophisticated software (VE.Bus Quick Configure and VE.Bus System Configurator) is available to configure several new and advanced features.